Advanced Contact Technology
www.multi-contact.com 1 / 8
PV-ADBP3/.../GWD PV-ADBP3/.../GWD
MC-K.../PV-ADBP3/.../GWD MC-K.../PV-ADSP3/.../GWD
MA223 (it_en)
Instruzioni per il montaggio
MA223 (it_en)
Assembly instructions
Connettore femmina per montaggio a pannello
PV-ADBP3/.../GWD
Connettore maschio per montaggio a pannello
PV-ADSP3/.../GWD
Connettore femmina per montaggio a pannello
con cavor MC-K.../PV-ADBP3/.../GWD
Connettore maschio per montaggio a pannello
con cavo MC-K.../PV-ADSP3/.../GWD
PV-Female panel receptacle PV-ADBP3/.../GWD
PV-Male panel receptacle PV-ADSP3/.../GWD
PV-Female panel receptacle with cable
MC-K.../PV-ADBP3/.../GWD
PV-Male panel receptacle with cable
MC-K.../PV-ADSP3/.../GWD
Indice
Istruzioni per la sicurezza ............................................................2
Utensili di montaggio ................................................................3
Cavo de collegamento ...............................................................3
Preparazione del cavo ................................................................4
Raccordi mediante crimpatura ..................................................4
Crimpatura ................................................................................. 4
con pinza per crimpare PV-CZM-16100A ...............................4
Montaggio dei connettori a pannello ........................................5
Angolo di curvatura del cavo ..................................................... 6
Connessione ..............................................................................6
Content
Safety Instructions ......................................................................2
Tools required ............................................................................3
Connecting lead ........................................................................3
Cable preparation ......................................................................4
Crimp connections ....................................................................4
Crimping .................................................................................... 4
with crimping pliers PV-CZM-16100A ....................................4
Assembly of panel receptacles .................................................. 5
Cable routing .............................................................................6
Engagement ..............................................................................6
Connettore femmina per montaggio a pannello
Female panel receptacle
Connettore maschio per montaggio a pannello
Male panel receptacle
con cavo / with cable con cavo / with cable
Etichetta adesiva
Sticker
Dati tecnici Technical data
Sistema di connettori Connector system Ø 3mm
Tensione misurata Rated voltage 1000V DC (IEC)
Corrente nominale Rated current
20A (2,5mm
2
, 4mm²)
30A (6mm²)
Tensione di prova Test voltage 6kV (50Hz, 1min.)
Intervallo di temperatura ambiente Ambient temperature range -40°C...+85°C (IEC)
Temperatura limite superiore Upper limiting temperature 105°C (IEC)
Classe di protezione, innestato
non innestato
Degree of protection, mated
unmated
IP65
IP2X
Cat. di sovratensione / Grado di imbrattamento Overvoltage category / Pollution degree CATIII / 2
Resistenza di contatto dei connettori a innesto Contact resistance of plug connectors 0,5mΩ
Classe di protezione Safety class II
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Assembly instructions

Advanced Contact Technology www.multi-contact.com 1 / 8PV-ADBP3/.../GWD PV-ADBP3/.../GWDMC-K.../PV-ADBP3/.../GWD MC-K.../PV-ADSP3/.../GWDMA223 (it_e

Page 2 - 2 / 8 www.multi-contact.com

Advanced Contact Technology2 / 8 www.multi-contact.comIstruzioni per la sicurezza Safety InstructionsI prodotti possono essere montati e installati s

Page 3

Advanced Contact Technology www.multi-contact.com 3 / 823PV-CZM-16100A145Utensili di montaggio Tools required(ill. 1)Spela fi li PV-AZM... inclusa la

Page 4 - Crimpatura Crimping

Advanced Contact Technology4 / 8 www.multi-contact.com76LQ892,5mm24mm26mm2Preparazione del cavo Cable preparation(ill. 6 / Tab. 1)Spellare il cavo.

Page 5 - Assembly of panel receptacles

Advanced Contact Technology www.multi-contact.com 5 / 810max. 5 mm+0.2- 0, 4Ø12,511121314Montaggio dei connettori a pannelloAssembly of panel recept

Page 6 - Connessione Engagement

Advanced Contact Technology6 / 8 www.multi-contact.comAngolo di curvatura del cavo Cable routingFare riferimento ai dati del costruttore per il minim

Page 7 - Advanced Contact Technology

Advanced Contact Technology www.multi-contact.com 7 / 8Note / Notes:

Page 8

Advanced Contact TechnologyFabbricante/Producer:Multi-Contact AGStockbrunnenrain 8CH – 4123 AllschwilTel. +41/61/306 55 55Fax +41/61/306 55 56mail