Advanced Contact Technology
www.multi-contact.com 1 / 8
PV-JB/WL-H
MA269 (de_en)
Montageanleitung
MA269 (de_en)
Assembly instructions
PV-JB/WL-H PV-JB/WL-H
Inhalt
Sicherheitshinweise....................................................................2
Erforderliches Werkzeug �����������������������������������������������������������3
Vorbereitung der Flachbandleiter ����������������������������������������������3
Vorbereitung der Paneldose ������������������������������������������������������4
Montage der Paneldose auf die Rückwand der
PV-Module ��������������������������������������������������������������������������������� 4
Flachbandleiter kontaktieren �����������������������������������������������������5
Aufsetzen des Deckels ��������������������������������������������������������������6
Technische Daten ����������������������������������������������������������������������7
Notizen ��������������������������������������������������������������������������������������8
Content
Safety Instructions ......................................................................2
Tools required ���������������������������������������������������������������������������3
Preparing the ribbon conductors �����������������������������������������������3
Preparing the junction box ��������������������������������������������������������4
Mounting the junction box on the back
of the PV module ���������������������������������������������������������������������� 4
Connecting ribbon conductors ������������������������������������������������� 5
Assembly of the lid �������������������������������������������������������������������� 6
Technical data ��������������������������������������������������������������������������� 7
Notes ����������������������������������������������������������������������������������������8
+
-
+
-
Engineering considerations according to UL File E335016
File E335016, Vol 1, Sec� 1
ENGINEERING CONSIDERATIONS:
Use - For use only with complete equipment where the acceptability of the combination is determined by Underwriters Labora-
tories Inc�
Conditions of Acceptability - In order to be judged acceptable as a component of electrical equipment, the following condi-
tions should be met:
1� These devices are intended for use with single-conductor cable and have been evaluated for strain relief of (ZKLA PV-Wire / TYLZ USE-2
Cable) Photovoltaic Cable, 12 AWG, and metric size cable of 4 mm², 7�05 mm cable outside diameter
2� The suitability of the mounting means to the backsheet of the end-product module shall be determined in the end use�
3� The UL 1703 Temperature test, Strain Relief test, Water Spray, Wet Insulation Resistance and Humidity cycling test sequences, shall be
conducted in the end use equipment�
4� These components have not been assessed for a maximum series fuse amp rating� The maximum series fuse amp rating should be as-
sessed in the end product�
5� These devices should be used only where they will not interrupt current. In addition, the need to include specic instructions in the end use
equipment’s manual describing the method of achieving disconnect while not under load should be considered�
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Assembly instructions

Advanced Contact Technology www.multi-contact.com 1 / 8PV-JB/WL-HMA269 (de_en)MontageanleitungMA269 (de_en)Assembly instructionsPV-JB/WL-H PV-JB/WL-

Page 2 - 2 / 8 www.multi-contact.com

Advanced Contact Technology2 / 8 www.multi-contact.comSicherheitshinweise Safety InstructionsDie Montage und Installation der Produkte darf ausschlie

Page 3

Advanced Contact Technology www.multi-contact.com 3 / 835124Erklärung der Symbole Explanation of the symbolsWarnung vor gefährlichem elektrischen Sc

Page 4 - 4 / 8 www.multi-contact.com

Advanced Contact Technology4 / 8 www.multi-contact.com7896Vorbereitung der Paneldose Preparing the junction box(ill. 6)Um ein Verschmieren der Siliko

Page 5

Advanced Contact Technology www.multi-contact.com 5 / 810111213Flachbandleiter kontaktieren Connecting the ribbon con-ductorsOption 1: Flachbandleit

Page 6 - Option 3: Soldering the rib

Advanced Contact Technology6 / 8 www.multi-contact.com1415X161718(ill. 14)Die Klemmfeder wird von oben auf die Kontaktfahnen aufgedrückt�(ill. 14)Pre

Page 7

Advanced Contact Technology www.multi-contact.com 7 / 821192022(ill. 19 + 20)Das Lötbild sollte wie folgt aussehen�Die Lötparameter sind entsprechen

Page 8

Advanced Contact TechnologyHersteller/Producer: Multi-Contact Essen GmbH Westendstrasse 10 DE – 45143 Essen Tel. +49 / 201 / 83105-0 Fax +49 / 201 /

Comments to this Manuals

No comments